Explosion Prevention in New Spheres Inside the Cockpit of the CO.Pilot

The topic of “explosion safety” is widespread for plant operators and OEM´s when it comes to handling or transporting combustible dusts. Despite the common assumption that an increased risk of explosion only exists for gases, enormous forces can also be released by explosive dust- / air mixtures.

To help minimize the risk of explosions when handing combustible dusts, it is important to understand the requirements for an explosion and the respective dust safety characteristics, which are described below. The following picture shows the explosion pentagon which must be taken into account.

The following conditions must exist for an explosion to occur within a production facility or machine:

fig1_April.jpeg

Fig. 1: Explosion pentagon

If any one of the afore mentioned prerequisites is eliminated, explosion prevention has intrinsically been practiced. However, if this is not possible at all times and in all operating states, explosion hazards will still be present. In that case, it is necessary to divide any potentially explosive atmospheres into zones and systematically apply safety measures.

Drying processes in particular are used in many industries to produce material, for easier storage, more efficient transport and a longer shelf life. However, the combination of moisture extraction and high temperatures creates an increased risk of both fire and explosions.

If fires and/or explosions occur in drying plants, which are usually very large, the situation is not only extremely dangerous for the machines and the business, but especially for the employees on site.

Operators of spray dryers must combat a particular type of ignition source – namely smouldering nests that can lead to spontaneous combustion if the material undergoes excessive caking. Caking occurs due to sub-optimal drying of the material and its initially high moisture content. The caked material is then insulated against the surrounding air by a build-up of moist material. The high temperatures ensure that the caked material is continuously heated until a biological reaction takes place involving protein, carbohydrates and water – known as the Maillard reaction. The Maillard reaction generates additional heat that cannot be dissipated due to the insulating layer of caked material. This exothermic process continues to accelerate until spontaneous combustion finally occurs.

Caking of this kind can build up both on the nozzles and the inner wall of the spray dryers. If the nozzle malfunctions, droplets may drip into the fluid bed and cause further clumping. If a smouldering nest is able to form, this can ignite the explosive atmosphere inside the dryer or the downstream machinery.

How can such conditions, which are frequently encountered in practice, be prevented?

Everything starts with the human factor, i.e. properly trained personnel for the respective processes. Optimal process control is also required to avoid caking. But without precise and reliable information/measurements, this is virtually impossible, even for specialists. Nowadays, humidity and one of the by-products of spontaneous combustion at early stages – carbon monoxide (CO) – are used as indicators to ensure a smooth and thus safe process. However, the fact that combined measurement systems cannot clearly distinguish between these two indicators is problematic and can result in inaccurate measurements.

The REMBE CO.Pilot – Synergistic CO and Humidity Measurement

The REMBE CO.Pilot autonomously performs continuous comparison of measured gas data with a synchronized database of stored reference gases that serve as "fingerprints" of the selected process and combustion gases. This allows the possibility to perform a real-time check to continuously verify the measurement accuracy as a self-calibration. At the same time, the real-time fingerprint analysis eliminates the cross-sensitivity to other gases in the measurement spectrum which is problematic with other commercial gas analysers.

To ensure a reliable measurement of the operating status, samples are sucked in from all of the dryer's relevant supply and exhaust air ducts under very high vacuum. REMBE calculates the delta CO value on the basis of the absolute values measured at the individual measuring points. This value is the mathematical difference between the CO content of the extract air and the CO content of the supply air. Thus, only events that actually occur in the respective process are detected. External factors that may disturb the measurement process can thus be ignored.

A proprietary evaluation algorithm, the REMBE Flow Algorithm, (RFA), enables the measured supply and exhaust gas stream values to be compared in real time. As a result, the REMBE CO.Pilot is the first system on the market that makes it possible to adjust the individual alarm limits and gas residence times for the individual measuring points in the dryer's various air throughputs without any delays. The ratios of the different supply air channels and the  associated predicted process gas streams are analysed via the software and calculated to determine an upset condition in the incipient stage.

Thus, if an increased carbon monoxide concentration is detected due to spontaneous combustion during the process, countermeasures can be initiated immediately.

But what does this mean in detail?

This special sampling process eliminates the need for costly and error-prone gas treatment, thus ensuring that the CO.Pilot is less susceptible to faults and requires less maintenance. Furthermore, this measurement method can make recurring calibrations unnecessary. Due to the precise measurement technology and the reproducible results, false alarms and downtimes can also be avoided. In combination with moisture measurements, the entire drying process can be optimally controlled, significantly increasing the energy efficiency of the system.

fig_2_april.jpeg

Fig. 2: REMBE CO.Pilot